ScanEM-Q probes were designed in cooperation with FCC engineers to FCC specification.

ScanEM-Q Probes
Specification

Parameter

ScanEM-QC Probes
CTK019

ScanEM-Q Probes
CTK017

 

The main difference between ScanEM-QC and ScanEM-Q probes is that ScanEM-Q probes do not provide AC/DC output and work only in a self-contained mode as E- and H-field "sniffers."

Probe

ScanEM-EQC

ScanEM-HQC

ScanEM-EQ

ScanEM-HQ

Type

Radiated (electric)

Conducted (magnetic)

Radiated (electric)

Conducted (magnetic)

Frequency Range

2MHz .. 2GHz

0.15 .. 30MHz

2MHz .. 2GHz

0.15 .. 30MHz

Self-Indication

5-LED color level bar; Speaker (tone pitch proportional to the field strength)

Output

AC and DC; SMB jack

N/A

Sensitivity

Per FCC requirements

AC Output Range

0..1V p-p

 

 

DC Output Range (>1MOhm load)

0..2V

Dimension (approx.)

6.18" x 1.21" x 0.76" (157mm x 31mm x 20mm)

Weight (approx.)

2.25oz (65g) each

Batteries

2 AAA (included)

Content of ScanEM Kits (see separate page for ScanEM probes)

ScanEM-QC kit model CTK019

ScanEM kit model CTK017

  • ScanEM-EQC probe
    ScanEM-HQC probe
    6' (1.8m) SMB/BNC cable
    Heavy-duty plastic storage case
    User's Guide
    Batteries
  • ScanEM-EQ probe
    ScanEM-HQ probe
    Heavy-duty plastic storage case
    User's Guide
    Batteries
  • Ó 1999 Credence Technologies, Inc. Mail comments to webmaster@credencetech.com
    Aware, EMAlert, EM Event, EMEye and ScanEM are trademarks of Credence Technologies, Inc.
    Products are covered by patents or are patent pending. All specifications are subject to change without notice.