ScanEM Probes |
||||||
|
Parameter |
ScanEM-C Probes |
ScanEM Probes |
||||
|
|
The main difference between ScanEM-C and ScanEM probes is that ScanEM probes do not provide AC/DC output and work only in a self-contained mode as E- and H-field "sniffers." |
|||||
|
Probe |
ScanEM-EC |
ScanEM-HC |
ScanEM-E |
ScanEM-H |
||
|
Field |
Electric |
Magnetic |
Electric |
Magnetic |
||
|
Frequency Range |
2MHz..2GHz |
0.1..100MHz |
||||
|
Self-Indication |
5-LED color level bar; Speaker (tone pitch proportional to the field strength) |
|||||
|
Output |
AC and DC; SMB jack |
N/A |
||||
|
Sensitivity |
-10dBm/(V/m) |
-10dBm/mT |
|
|||
|
AC Output Range |
0..1V p-p |
|||||
|
DC Output Range (>1MOhm load) |
0..2V |
|||||
|
Dimension (approx.) |
5.75" x 1.21" x 0.76" (146mm x 31mm x 20mm) |
|||||
|
Weight (approx.) |
2oz (57g) each |
|||||
|
Batteries |
2 AAA (included) |
|||||
Content of ScanEM Kits (see separate page for ScanEM-Q)
|
ScanEM-C kit model CTK015 |
ScanEM kit model CTK010 |
|
ScanEM-H probe Heavy-duty plastic storage case User's Guide Batteries |
|
ScanEM-EC and HC Frequency Response vs. "Standard" Passive Probes |
|
|
|
|
Ó
1999 Credence Technologies, Inc. Mail comments to webmaster@credencetech.com